BENDER LINETRAXX RCMS460-L-1 Residual Current Evaluator RCMS460 DIN Rail

BENDER LINETRAXX RCMS460-L-1 Residual Current Evaluator RCMS460 DIN Rail

$1,199.99
Skip to product information
BENDER LINETRAXX RCMS460-L-1 Residual Current Evaluator RCMS460 DIN Rail
1/12

BENDER LINETRAXX RCMS460-L-1 Residual Current Evaluator RCMS460 DIN Rail

$1,199.99
Only 1 available
BENDER LINETRAXX RCMS460-L-1 Residual Current Evaluator DC 16…94 V / AC 16…72 
In excellent used condition, pulled from working control cabinets that were in operation for less than 1 year. User manual included.
  • Response Value AC/DC 6mA...20A  42...2000Hz
  • Supply Voltage AC 16...72 V / DC 16...94 V
  • Power Consumption 10 VA
  • Relay Contacts AC 250 V 5 A
From the Manufacturer:
  • Optional AC, pulsed DC or AC/DC sensitive measurement by selecting the respective measuring current transformer for each channel
  • True r.m.s. value measurement
  • 12 measuring channels per device for residual current measurement or digital input
  • Up to 90 RCMS… monitors, up to1080 measuring channels in the system
  • Fast parallel scanning for all channels
  • Response ranges: 10 mA…10 A (0…2000 Hz), 6 mA…20 A (42…2000 Hz), 100 mA…125 A (42…2000 Hz) RCMS…-D4
  • Preset function
  • Adjustable time delays
  • The frequency response characteristics can be set for the protection of persons, fire and plant protection
  • History memory with date and time stamp for 300 data records
  • Data logger for 300 data records/channel
  • Analysis of the harmonics, DC, THD
  • Two alarm relays with one changeover contact each
  • Device version RCMS490 with one alarm contact per channel
  • N/O or N/C operation and fault memory selectable
  • Connection external test/reset button
  • Backlit graphical display (7-segment display) and alarm LEDs
  • Data exchange via BMS bus
  • Password protection for device setting
  • Continuous CT connection monitoring
  • RoHS compliant
Applications:
  • Measuring and evaluating residual, fault and rated currents of loads and installations in the frequency range of
  • - 0…2000 Hz (CTUB100 or CTBS25 series measuring current transformers),
  • - 42…2000 Hz (CTAC…, WR…, WS…, WF… series measuring current transformers).
  • Monitoring of currents regarded as fire hazards in flammable atmospheres
  • EMC monitoring of TN-S systems for “stray currents” and additional N-PE connections.
  • Monitoring of N conductors for overload caused by harmonics
  • Monitoring of PE and equipotential bonding conductors to ensure they are free of current
  • Residual current monitoring of stationary electrical equipment and systems to determine test intervals which meet practical requirements in compliance with the accident prevention regulations DGUV V3 (Germany).
  • Personnel and fire protection due to rapid disconnection
  • Monitoring of digital inputs
For more information: bender.de/en/products/residual-current-monitoring/linetraxx_rcms460-l